A customer wants to deploy a FlexPod Datacenter solution in a limited amount of rack space. After planning for the networking and storage devices required for the deployment, they realize they have six rack units of space remaining. They need to install as many servers as possible in this available rack space.
In this scenario, which solution allows them to accomplish their objective?
Athree Cisco UCS C4200 rack servers
Bfour Cisco UCS B480 M blade servers
Csix Cisco UCS C220 M5 rack servers
Deight Cisco UCS B200 M5 blade servers
An administrator wants to ensure secure authentication while accessing a NetApp ONTAP system.
In this scenario, which two access methods should be used? (Choose two.)
ARSH
BSSH
CHTTPS
DHTTP
A customer has decided to deploy Red Hat OpenShift on a FlexPod solution, based in a published Cisco Validated Design. The customer intends to use the NetApp Trident to attach persistent storage to the customer’s containers from the customer’s NetApp AFF controllers.
In this scenario, which two storage protocols are supported? (Choose two.)
AiSCSI
BFC
CNFS
DSMB
A partner wants to develop a FlexPod Datacenter solution for a customer that will use Cisco ACI.
In contrast to a FlexPod solution with NX-OS, which two additional requirements must be satisfied? (Choose two.)
AUse two Cisco Application Policy Infrastructure Controllers (APICs)
BDeploy the Cisco Nexus 900 Series Switches in a core-edge topology
CDeploy the Cisco Nexus 900 Series Switches in a leaf-spine topology
DUse three Cisco Application Policy Infrastructure Controllers (APICs)
Question 6
Not found on the official NetApp certification pages I could access for NS0-175
0
Question 7
Not found on the official NetApp certification pages I could access for NS0-175
Question 8
Not found on the official NetApp certification pages I could access for NS0-175
Question 9
Not found on the official NetApp certification pages I could access for NS0-175
Question 10
Not found on the official NetApp certification pages I could access for NS0-175
Question 11
Not found on the official NetApp certification pages I could access for NS0-175
Question 12
Not found on the official NetApp certification pages I could access for NS0-175
Question 13
Not found on the official NetApp certification pages I could access for NS0-175
Question 14
Not found on the official NetApp certification pages I could access for NS0-175
Question 15
Not found on the official NetApp certification pages I could access for NS0-175
Question 16
Not found on the official NetApp certification pages I could access for NS0-175
Question 17
Not found on the official NetApp certification pages I could access for NS0-175
Question 18
Not found on the official NetApp certification pages I could access for NS0-175
Question 19
Not found on the official NetApp certification pages I could access for NS0-175
Question 20
Not found on the official NetApp certification pages I could access for NS0-175
Question 21
Not found on the official NetApp certification pages I could access for NS0-175
Question 22
Not found on the official NetApp certification pages I could access for NS0-175
Question 23
Not found on the official NetApp certification pages I could access for NS0-175
Question 24
Not found on the official NetApp certification pages I could access for NS0-175
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ad
Want a break from the ads?
Become a Supporter and enjoy a completely ad-free experience, plus unlock Learn Mode, Exam Mode, AstroTutor AI, and more.
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
A customer has a FlexPod configuration that supports FC and uses Cisco MDS switches. The customer wants to add a 48-Port 32 Gbps Advanced Fibre Channel Switching blade to support both 32 Gbps FC and 32 Gbps NVMe-oF.
In this scenario, which Cisco switch is appropriate?
AMDS 9250i
BMDS 9706
CMDS 9148S
DMDS 9396S
A customer wants to add 40 Gbps networking capabilities to a FlexPod Datacenter 10 Gbps environment.
Which two Cisco components support this speed? (Choose two.)
ACisco Nexus 9504
BCisco UCS 1440 VIC
CCisco Nexus 3550-F
DCisco UCS 1455 VIC
You received from a customer the requirements shown below.
-- 25 servers
-- 25GbE connectivity
-- NFS and iSCSI protocols
-- 30 TB flash storage
-- 50 TB hybrid storage
In this scenario, which FlexPod solution would satisfy the requirements?
A customer with a FlexPod solution wants to expand their NetApp ONTAP 9.7 switchless cluster. The new hardware must support expansion slots. In addition, they will also upgrade to a 100 Gbps-capable cluster interconnect switch for future growth.
In this scenario, which two additional components will satisfy the requirement? (Choose two.)
ANexus 3232C
BNexus N3132Q-V
CNetApp FAS2720
DNetApp AFF A400
A customer is performing a server refresh of their FlexPod solution to accommodate business growth. The customer is interested in using Cisco C-Series servers, and supporting multiple 40 Gbps link to each server, upgrading from the existing 10 Gbps links.
Which two VICs support these requirements? (Choose two.)
ACisco UCS 1480 VIC
BCisco UCS 1497 VIC
CCisco UCS 1495 VIC
DCisco UCS 1440 VIC
You are designing a FlexPod solution with secure multitenancy for a company. Each department in the company wants to use their own storage and to be integrated with Windows Active Directory.
In this scenario, which three technologies should be included in the design? (Choose three.)
AIPspaces
BNVMe
CS3
DCIFS
EStorage Virtual Machine
In which two sources would you verify scale out maximums for NetApp and Cisco UCS environments? (Choose two.)
ACisco Configurations Limits
BCisco UCS Hardware and Software Compatibility List
CNetApp Hardware Universe
DNetApp Interoperability Matrix
A customer wants to replace their Cisco UCS 6248UP with the current Cisco UCS 6454. They are currently using six 16 Gbit uplinks per Fabric Interconnect for FC and do not want to change the speed and number of ports used.
In this scenario, what is the minimum number of unified ports that must be configured for FC for a comparable configuration?
A8
B6
C16
D12
You are sizing a FlexPod Datacenter solution for multitenancy use.
What are two important platform scaling considerations in this scenario? (Choose two.)
Amaximum NetApp ONTAP cluster limits
Bmaximum NetApp ONTAP storage VM limits
Cmaximum Cisco vPC interfaces between Fabric Interconnects
Dmaximum Cisco L1, L2 interfaces between Fabric Interconnects
A customer wants to use a Cisco Nexus 93180YC-FX switch to support the FC protocol for booting from SAN without having to deploy additional Cisco 900 Series MDS switches in their FlexPod Datacenter configuration.
In this scenario, what is required for this solution?
AThe customer must enable the FC license on the 93180YC-FX switch
BThe customer must deploy the 93180YC-FX switch as part of a Cisco ACI fabric
CThe customer must directly connect the NetApp AFF system to the Cisco UCS Fabric Interconnects
DThe customer must add an expansion FC module to the 93180YC-FX switch
You are designing a multi-site FlexPod Datacenter solution for a customer using MetroCluster over IP. The design should include a single set of compliant switches for the environment.
Which two features are required to satisfy this requirement? (Choose two.)
Asupport for Fibre Channel ports
Bsupport for an MTU size of 9216
Csupport for unified switch ports
Dsupport for QoS
A customer is verifying that they have separation on their FC switch fabric to protect their FlexPod solution from their other storage devices.
Which two technologies enable the customer to accomplish this task? (Choose two.)
AWWPN zoning
BVASN
CIQN igroup
DVLAN
A customer is deploying a FlexPod Datacenter and planning to boot from SAN each their UCS blades using the Fibre Channel Protocol.
In this scenario, which three actions would accomplish their objective? (Choose three.)
AUse only a pair of Cisco Nexus 9318YC-FX switches
BCreate an igroup on the NetApp ONTAP storage system with the appropriate IQNs
CUse only a pair of Cisco Nexus 9336C-FX2 switches
DUse a pair of Cisco MDS 9148T and a fair of Cisco 9336C-FX2 switches together
ECreate an igroup on the NetApp ONTAP storage system with the appropriate WWPNs
Your environment currently has a 12-node NetApp cluster serving iSCSI. You need to add at least four more nodes to serve FC to your environment.
In this scenario, what should you do?
AYou can safely add up to 4 more storage controllers in the current cluster
BYou can safely add up to 6 more storage controllers in the current cluster
CYou must create a new cluster with the new storage controllers
DYou can safely add up to 12 more storage controllers in the current cluster
A customer plans to decommission a Cisco UCS B-Series server, as part of this action, the customer disassociates the service profile from the currently assigned server.
Which action is performed by UCS Manager in this scenario?
AIt reboots the primary Fabric Interconnect immediately
BIt recalculates the power allotment for each blade server within the chassis
CIt reboots the secondary Fabric Interconnect immediately
DIt powers down the server
You want to direct-connect NetApp storage to a UCS Mini over IP.
In this scenario, which storage protocol is supported?
ACIFS
BFC
CS3
DiSCSI
You are designing a FlexPod solution that requires 100GbE connectivity between all components.
In this scenario, what are two NetApp Controller types that would satisfy the requirement? (Choose two.)
ANetApp AFF A220
BNetApp AFF C190
CNetApp AFF A800
DNetApp AFF A400
A customer is designing a FlexPod solution that must satisfy the requirements shown below:
-- have disaster recovery to an alternative data center,
-- must have continuous replication of data for a database,
-- must leverage a 100Gbps capable switch,
-- have a maximum distance of 700 km.
In this scenario, which two components would be used to satisfy the requirements? (Choose two.)
AMetroCluster FC
BCisco Nexus 3232C
CMetroCluster IP
DCisco MDS 9132T
You are asked to design a new FlexPod solution that will host VMware virtual machines using NFS datastores, file services using SMB, and NFS-mounted home directories. You need to ensure that the network traffic of these three use cases are isolated?
In this scenario, which supported end-to-end network topology would be used to accomplish this task?