About the Exam

This exam validates the ability to design Cisco and NetApp FlexPod solutions for a variety of business workloads. It focuses on understanding FlexPod hardware components, selecting appropriate hardware for customer requirements, and related networking, security, and tools topics. Passing demonstrates validated skills for planning FlexPod deployments in line with NetApp FlexPod design expectations.

Exam Topics

  • FlexPod Design0%
  • Networking0%
  • Security0%
  • Tools0%

How to Use This Practice Exam

  1. Browse — Read each question, select your answer, and reveal the explanation.
  2. Exam Mode — Simulate real exam conditions with a timed session and score report.
  3. Learn Mode — Spaced repetition schedules questions you struggle with for long-term retention.

Download the Full Exam PDF

Get every question and answer in a clean, printable PDF built for offline study. Purchase once, keep permanent access, and re-download the latest version anytime.

Last updated July 9, 2026 at 2:04 PM

Topic filter
Question status
Question sort
Questions per page

QuestionQ1

VerifiedFlexPod Design

You are designing a multi-site FlexPod Datacenter solution for a customer that uses MetroCluster over IP. The design must include a single set of compliant switches for the environment.

Which two features are required to meet this requirement?

Choose two
Explanation

MetroCluster-compliant switches carrying MetroCluster IP traffic must support quality of service (QoS) and traffic classification, and they must be configured with an MTU of 9216. Fibre Channel and unified-port capabilities are not required for a MetroCluster IP switch deployment.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!

QuestionQ2

VerifiedFlexPod Design

A customer is deploying a FlexPod Datacenter and intends to boot each of their UCS blades from SAN by using the Fibre Channel Protocol.

In this scenario, which three actions would achieve the objective?

Choose three
Explanation

Fibre Channel initiators are identified by WWPNs, so an ONTAP igroup for FC boot LUN access must contain the appropriate UCS blade WWPNs; IQNs are iSCSI initiator identifiers. FlexPod can use FC-capable Cisco Nexus 93180YC-FX switches for SAN switching, or use Cisco MDS switches for the FC SAN together with Cisco Nexus 9336C-FX2 switches for Ethernet connectivity.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!

QuestionQ3

VerifiedTools

A customer intends to decommission a Cisco UCS B-Series server. As part of this process, the customer disassociates the service profile from the server currently assigned to it.

Which action does UCS Manager perform in this scenario?

Explanation

When a service profile is disassociated, Cisco UCS Manager attempts to shut down the server’s operating system and forces the server to shut down if it does not do so within a reasonable time.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!

QuestionQ4

VerifiedFlexPod Design

A customer is designing a FlexPod solution that must meet these requirements:

  • Provide disaster recovery to an alternate data center.
  • Provide continuous data replication for a database.
  • Use a switch capable of 100 Gbps.
  • Support a maximum distance of 700 km.

Which two components would satisfy these requirements?

Choose two
Explanation

MetroCluster IP provides synchronous replication and continuous availability between two sites and supports distances of approximately 700 km in a FlexPod architecture. A Cisco Nexus 3232C is supported for MetroCluster IP and supports native 100 Gbps inter-switch links. MetroCluster FC supports only approximately 300 km, so it does not meet the distance requirement.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!

QuestionQ5

VerifiedFlexPod Design

A customer has chosen to deploy Red Hat OpenShift on a FlexPod solution based on a published Cisco Validated Design. The customer plans to use NetApp Trident to attach persistent storage from the customer’s NetApp AFF controllers to the customer’s containers.

In this scenario, which two storage protocols are supported?

Choose two
Explanation

NetApp Trident on the applicable FlexPod OpenShift design provides persistent container storage from NetApp AFF through NFS for file-based volumes and iSCSI for block-based volumes. The Cisco validated design identifies NFS and iSCSI storage classes for Trident-backed OpenShift storage.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!