QuestionQ58

VerifiedDetermine customer's requirements

Waratah Hospital, located in Australia, plans to relocate many data-center services to a new facility. (The remaining legacy data center is outside this project’s scope.) Waratah Hospital has engaged an external consultant to help design the new data-center network.

Based on the data-center network-infrastructure requirements, the external consultant has produced a high-level design. The design document is summarized below.

Requirements and information:

  • Six racks in the data-center room (a single row).
  • Redundant top-of-rack leaf switches with back-to-front cooling in every rack, delivering 10/25 Gbps connectivity to servers, storage, and other devices.
  • Four 100 GbE uplinks per leaf switch.
  • The customer requested that all switch ports face the rear of the racks (the hot aisle).
  • OOB management for servers, storage, and network devices must be delivered through an external switch with back-to-front cooling. This switch must be included in the solution. One OOB switch provides connectivity for two racks.
  • Core equipment for the OOBM network is being reused.
  • Middle-of-row spine switches.
  • The data center must connect to the hospital building through links providing 400 Gbps.
  • Internet access is supplied through an existing firewall cluster with two firewalls, one in each data room. The second firewall operates in standby mode, and VRRP is used for firewall failover. The data-center network must connect to these firewalls with links totaling 100 Gbps.
  • The external link is a single-mode-fiber (OS2) dark-fiber direct link. The distance to the main hospital is 1.5 KM. The links will terminate on two core switches in the hospital.

The customer also requires:

  • 99.999% uptime for this life-critical environment.
  • Planned and unplanned downtime must be minimized.
  • Software upgrades are permitted only once per year, with close to zero downtime.
  • All life-critical resources are accessed locally, and all resources are within the hospital campus.
  • Waratah Hospital requires a highly secure data-center environment. Encrypted wire-speed connectivity between the data room and the hospital is mandatory because the link between the buildings crosses a public road.
  • Waratah Hospital has a mix of virtualized (vSphere) servers, Nutanix storage, bare-metal servers, backup servers, and other devices.

Previously, the hospital experienced a security breach that caused data loss, network downtime, and identity theft.

Refer to the scenario. You are deciding between the CX 9300 and CX 8325 switches for the border leaf switches. Which hard customer requirement affects this decision?

Explanation

Wire-speed encryption over the inter-building fiber requires switch hardware that supports MACsec. The CX 9300S has embedded MACsec capabilities for secure data-center-interconnect deployments; Aruba’s data-center design guidance identifies MACsec-capable CX 9300S ports, while the CX 8325 is not included in that MACsec support list. This makes hardware encryption a mandatory platform-selection criterion.

Learn more