QuestionQ57

VerifiedRouting

A global cruise-line company must refresh its current fleet. It will refresh the ship’s “insides” to be cost-effective and increase sustainability, replacing all WLAN/LAN hardware. During this refresh, the company will retain its existing security requirements. The CIO also wants to minimize unused switch ports. Any future expansion will always require a hardware refresh. The company begins with its smallest ship, supporting a maximum of 800 guests.

Each ship has a LAN infrastructure comprising two core switches, up to 10 redundant distribution switches, and up to 500 access switches (400 cabins and 100 technical rooms). The core switches are in the ship’s MDF, and the distribution switches are in the IDFs. Every cabin and technical room receives one individual access switch.

The ship’s cabling structure will remain unchanged. Each IDF connects to the MDF using SMF, with two pairs available for the core-to-distribution interconnect. The MDF-to-IDF SMF run is under 300 meters (980 ft) and uses OS1 fiber. Each cabin connects to its IDF through one OM2 pair, with a maximum length of 60 meters (200 ft). Each technical room connects to its IDF through one OM2 pair, with lengths from 100 to 150 meters (320 to 500 ft).

For every cabin/technical room, the customer wants to replace its current fan-less 2530/2540 without changing requirements, except that the uplink to the distribution switch must be upgraded to 10GbE to accommodate increased network traffic, and technical rooms require redundant power.

The WLAN infrastructure will be refreshed 1:1, with no new cabling or AP locations. The WLAN uses 200/300-series indoor and outdoor APs running InstantOS (fewer than 300 APs), and the customer has no changes to WLAN requirements.

The cruise-line company will replace its current internet connection before the LAN/WLAN refresh. The new internet connection will provide 99.8% uptime, needed to keep the paid quest Wi-Fi operational. With this new internet connection, the CIO wants to base the design on Aruba’s ESP architecture because the internet connection is guaranteed.

Based on best practices, which optic type should be recommended for the connection between the IDF and the technical rooms?

Explanation

The 100–150 m technical-room links use OM2 multimode fiber. Aruba specifies 10G SFP+ LC LRM optics for up to 220 m over OM2 multimode fiber, while 10G SFP+ LC SR optics reach only 82 m over OM2. LRM therefore supports the required 10GbE distance on the retained cabling.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!