QuestionQ22

VerifiedManaging and Monitoring

A customer uses stacked CX 6200 and CX 6300 switches for access, with a VSX pair of CX 8325 switches as a collapsed core. 802.1X is used for authentication. Because cabling is limited, some unmanaged switches remain in use. At times, devices behind those switches cause network outages. The switch must send a warning to the helpdesk when the issue occurs. You have been asked to implement an effective solution to this problem.

What is the solution?

Explanation

AOS-CX loop protection is appropriate on access-edge ports because it detects Layer 2 loops involving unmanaged switches, which may not process spanning-tree BPDUs, and it is recommended for client-authenticated ports where 802.1X can prevent normal STP loop detection. Enabling the loop-detected SNMP trap sends a notification when loop protection detects an event. Aruba AOS-CX Loop protection Aruba AOS-CX loop-protect trap command

Learn more