QuestionQ31

Security Engineering

Within a SCADA environment, a business requires access to the historian server to collect metrics on the environment's functionality. Which of the following actions should be taken to meet this requirement?

  • A Isolating the historian server for connections only from the SCADA environment
  • B Publishing the C$ share from SCADA to the enterprise
  • C Deploying a screened subnet between IT and SCADA
  • D Adding the business workstations to the SCADA domain
Explanation

A screened subnet between the IT network and the SCADA environment creates a controlled security boundary for business access to historian data. It enables tightly restricted, monitored communications while keeping enterprise systems separated from critical industrial-control assets.