QuestionQ56

VerifiedBusiness Continuity

An administrator must ensure that an RF2 cluster can withstand the loss of an entire rack without adversely affecting workload performance. The current cluster configuration is as follows:

  • 30 nodes, distributed as 10 nodes per rack across three 42U racks
  • Each node is configured with 40 TB of usable all-flash storage (1.2 PB usable for the cluster total)
  • Current cluster storage utilization is 900 TB

Which configuration changes should be made to ensure that the cluster meets these requirements?

Explanation

An RF2 cluster designed to tolerate loss of any rack must retain sufficient usable capacity in the remaining racks. With 12 nodes per rack, failure of one rack leaves 24 nodes at 40 TB each, providing 960 TB of usable storage—enough for the 900 TB workload.