Refer to the exhibit.

Question Image

A Nutanix host is connected as illustrated, with br0-up configured for active/backup. Physical Switch 1 has a power outage, causing br0-up to fail over to eth2. The CVM and host become inaccessible. User VMs restart on other hosts in the cluster, disrupting those VMs.

Which configuration issue most likely caused this outage?

Explanation

An active/backup uplink bond can fail over successfully only when the backup uplink provides the same required network connectivity as the active uplink. If eth2's upstream switch port is missing a required VLAN, failover isolates the host and CVM from that VLAN and interrupts VM connectivity, causing the observed loss of access and VM disruption.