QuestionQ11

VerifiedAdvanced Configuration and Troubleshooting

An administrator is notified that storage in a Nutanix cluster is unavailable. The cluster has five nodes and is configured with a Fault-Tolerance level of 1 (FT-1).

During the investigation, the administrator determines the following:

  • All AHV hosts are powered on, and the CVMs are running.
  • Nodes A, B, and C connect to one top-of-rack switch.
  • Nodes D and E connect to a second top-of-rack switch.
  • The cluster status command run on Node A indicates that CVM services on Nodes D and E are down.

Which issue is causing the storage outage?

Explanation

An FT-1 configuration can tolerate the loss of only one node. Failure of the top-of-rack switch shared by Nodes D and E isolates both nodes’ CVMs simultaneously, so the cluster loses two nodes and exceeds its configured fault tolerance, causing storage to be unavailable.

Community Discussion

No comments yet. Be the first to start the discussion!