QuestionQ44

VerifiedONTAP SAN implementation and configuration

An administrator must configure Foreign LUN Import on a NetApp HA pair to migrate FCP LUNs from a third-party array while continuing to serve other LUNs.

Which two actions are necessary to complete this task?

Choose two
Explanation

FC Foreign LUN Import uses ONTAP as a SCSI initiator to read the foreign LUNs. The third-party array’s target ports must be zoned to ONTAP initiator ports so ONTAP can discover and import the source LUNs. FC FLI requires at least one FC port per controller that can operate in initiator mode; leaving the remaining FC ports in target mode allows the HA pair to continue serving host LUNs.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!