You connected your FAS8200 to a Brocade SAN switch. As shown in the exhibit, port 0e is unavailable.

In this scenario, which statement is correct?

  • A The incorrect SFP+ module is installed.
  • B The switch zoning is using the FC nodename.
  • C The incorrect firmware revision is installed.
  • D The switch port is configured for mode E_Port.
Explanation

An FC target port must use an FC SFP appropriate to the connected fabric. The port reports a 10 Gbit/sec SFP, but NetApp specifies an 8 Gb or 16 Gb SFP for Fibre Channel on the unified target adapter. A 10 Gb Ethernet SFP is therefore the incorrect module for this FC connection.