QuestionQ42

VerifiedONTAP SAN implementation testing and troubleshooting

A customer plans to connect a Linux server to a FAS8200 through Brocade FC switches. During initial configuration, the SVM does not log in to the fabric.

Which two statements are correct for this scenario?

Choose two
Explanation

ONTAP uses NPIV to present FC targets to a fabric, so NPIV must be enabled on every connected switch. The storage system is an end device and requires an F_Port; E_Ports are inter-switch-link ports. Zoning affects host-to-target access after fabric login, and ALUA is unrelated to the SVM's ability to log in to the FC fabric.

Learn more

Community Discussion