QuestionQ18

VerifiedONTAP SAN implementation and configuration

Select the Exhibit button.

Question Image

A customer wants to add a 2-port, 32 Gb FC card to support NVMe in an AFF A700 2-node cluster. Cards are currently installed in slots 1, 2, 4, 6, 8, and 9.

Referring to the exhibit, which slot number should be used?

Explanation

The 2-port 32 Gb FC adapter has a supported priority sequence of slots 9, 1, 10, 2, 11, 3, 7, 6, and 8. With slots 9 and 1 already populated, slot 10 is the highest-priority available supported slot.