QuestionQ48

VerifiedIntroduction to High-Availability in Clustered Data ONTAP

You receive the following error on a FAS2750 HA pair:

Mon Jun 24 00:27:30 UTC [NetappA: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Unknown device 0a.00.99:  
Check Condition: CDB 0x12: Sense Data SCSI:hardware error - (0x4 - 0x44 0x0 0x0) (0).  

The system is cabled as shown in the exhibit.

Question Image

What should you do to clear the error?

Explanation

A FAS2750 HA pair requires its SAS ports to be connected to the shelf IOM A and IOM B domains in the prescribed cross-controller topology. Incorrect SAS topology can produce an unknown-device check condition on port 0a. Restoring the installation-guide cabling resolves the connectivity error without replacing a controller.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!