A medical company has completed a safety-criticality analysis in accordance with the IEC 61508 standard. The software components that must be developed have been classified by Safety Integrity Level (SIL). Most components are rated SIL 1 or SIL 2, while a few are rated SIL 4.

Following discussions with the QA manager, the project has decided to follow the IEC 61508 recommendations for test coverage.

Which level and type of test coverage should, at a minimum, be used for components rated Safety Integrity Level (SIL) 2?

Explanation

IEC 61508-3 grades software testing techniques by the required safety integrity level. For SIL 2, structural testing should achieve complete statement coverage and complete decision coverage. Modified condition/decision coverage (MC/DC) and multiple-condition coverage impose stronger condition-level obligations intended for higher-integrity cases.