QuestionQ18

VerifiedIntroduction to Huawei Data Center Facility and Critical Power Solutions

Regarding the Huawei smart modular module solution, which of the following statements are correct?

A. FusionModule800 and FusionModule500 integrate cooling and electrical control. They are highly integrated and fully prefabricated, featuring a fully enclosed aisle with wet-film humidification and supporting smart mobile management.

B. Huawei FusionModule800 is a modular data center solution designed for financial outlets and small enterprise data centers. It is easy to deploy, clean, and reliable, and can perfectly meet the application requirements of these scenarios.

C. The FusionModule2000 adopts the simplified design concept. It has low footprint and high requirements on low floors. It does not require raised floors. It supports modular deployment and supports one-click commissioning. The implementation time is shortened from 30 days to 7 days.

D. In the FusionModule800 and FusionModule500, fire extinguishers can be deployed in the fire extinguishing module. The built-in fire extinguishing gas can meet the fire extinguishing requirements of the entire room.

Choose three
Explanation

FusionModule800 and FusionModule500 are Huawei's highly integrated, fully prefabricated micro/small modular data center products that combine UPS, PDU, cooling, monitoring, and cabinets in a single row or cabinet, use cold/hot aisle containment with wet-film humidification for efficient cooling, and support app-based smart mobile management — this matches official product specifications. FusionModule800 is specifically positioned by Huawei for financial outlets, government, education, and small/medium enterprise data center scenarios, offering fast (as little as 4-hour) deployment, cleanliness, and reliability suited to these use cases. FusionModule2000 uses a simplified architectural design that removes the need for a raised floor, supports fully modular deployment, and its one-click commissioning capability reduces implementation time from 30 days down to 7 days, as documented by Huawei. In contrast, while FusionModule800/500 do offer an optional in-cabinet/in-module fire extinguishing unit, this built-in gas capacity is designed and sized only to protect the module/cabinet itself, not the entire server room; whole-room fire protection still requires a separate room-level fire suppression system, making the claim about meeting entire-room requirements inaccurate.