QuestionQ29

VerifiedNG WDM Alarm Signal Flow Analysis

In a scenario where a non-convergence OTU processes OTN standard signals, A and B are both WDM sites. After the OTU board at station A receives an OTUk_TIM alarm on the client side, it sends an OTUk_BDI alarm upstream. When the TIM follow-up action is disabled, the alarm is not transmitted downstream. When the TIM follow-up action is enabled, an SF event is generated. The WDM side of the OTU board at station B reports the ODUk_PM_AIS alarm, which is transmitted downstream. The client equipment reports this alarm. After the WDM side of the OTU board at station B receives the OTUk_TIM alarm and the TIM follow-up action is disabled, the alarm is not transmitted downstream. When the TIM follow-up action is enabled, an SF event is generated. After the client side of station B processes the SF event, the client equipment reports the ODUk_PM_AIS alarm.

Explanation

For non-convergence OTU processing of OTN-standard signals, an OTUk_TIM condition sends OTUk_BDI upstream. Enabling the TIM follow-up response causes an SF event, whose downstream handling produces ODUk_PM_AIS at the client-facing side; disabling that response prevents downstream propagation. Huawei lists OTUk_TIM and ODUk_PM_AIS among OTU-board signal-failure conditions.