QuestionQ20

VerifiedNG WDM System Troubleshooting

If no bit-error test is carried out on an optical channel for 10 minutes, use the SDH analyzer at the local end to connect to the client-side port on the OTU board. The client-side port on the OTU board at the opposite end must be self-looped using a fiber. For this self-loop, a fixed attenuator must be added.

Explanation

A remote client-side fiber loop allows the local SDH analyzer to perform the optical-channel bit-error test over the complete path. A fixed optical attenuator in the self-loop keeps received optical power within the supported range and prevents receiver overload.