QuestionQ30

VerifiedNetwork Resiliency and virtualization

Refer to the exhibit.

Question Image

A VSX cluster has already been configured. You must validate the correct configuration for the Edge-1 switch, which connects to a CCTV provider that will install its switching infrastructure. The CCTV switches do not support STP.

What must be configured on the Edge-1 switch ports connected to CCTV-SW1 and CCTV-SW2 to prevent loop issues in the existing setup while providing automatic recovery?

Explanation

BPDU guard protects an STP edge port by disabling it when it receives a BPDU. BPDUs can be flooded back through the non-STP CCTV switching loop, causing the affected Edge-1 port to be disabled and breaking the loop. A BPDU-guard timeout automatically re-enables the port after the configured interval.