About the Exam

This professional-level exam leads to the HPE Aruba Networking Certified Professional - Data Center certification for candidates with three or more years of data center networking experience. Its 75 questions cover low-level design, installation, configuration, troubleshooting, monitoring, maintenance, optimization, and integration with servers, storage and hypervisors. Passing demonstrates the ability to deploy and run data center networks on HPE Aruba Networking switches.

Exam Topics

  • Plan the low-level design14%
  • Install the solution13%
  • Configure the solution23%
  • Troubleshoot15%
  • Create a monitored environment12%
  • Maintain and optimize12%
  • Integration11%

How to Use This Practice Exam

  1. Browse — Read each question, select your answer, and reveal the explanation.
  2. Exam Mode — Simulate real exam conditions with a timed session and score report.
  3. Learn Mode — Spaced repetition schedules questions you struggle with for long-term retention.

Download the Full Exam PDF

Get every question and answer in a clean, printable PDF built for offline study. Purchase once, keep permanent access, and re-download the latest version anytime.

Last updated September 8, 2026 at 8:19 PM

Topic filter
Retired questions
Question sort
Questions per page

QuestionQ10

Troubleshoot

Map the Data Plane Impact when Pensando Policy and Services Manager (PSM) is deployed in high availability (HA) and an HA issue occurs.

Drag & Drop
One PSM node fails or becomes unreachable.
The management plane is down between a DSS and the PSM.
Two PSM nodes fail or become unreachable.
Explanation

PSM HA has three PSM VMs, so losing one preserves quorum and configuration updates continue. A DSS that cannot reach the PSM cannot receive configuration changes, although existing stateful data-plane services continue. Losing two PSM nodes removes quorum; the PSM prevents logins and configuration changes to avoid split brain, while existing stateful services remain unaffected.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!

QuestionQ33

Troubleshoot

Map the management-plane impact when Pensando Policy and Services Manager (PSM) is deployed in high availability (HA) and an HA issue occurs.

Drag & Drop
Configuration changes are accepted by the PSM and applied to DSSes Metrics and logs are regularly collected.
Configuration changes are accepted by the PSM but will not take effect until the DSS and PSM can communicate. Metrics and logs will be buffered at the DSS as local memory availability permits.
The PSM does not allow new user logins and does not accept configuration changes, to avoid a “split-brain” scenario. Metrics and logs are not collected by the PSM but will be buffered at the DSS subject to local storage availability.
Explanation

A single PSM-node failure retains HA-cluster quorum, so configuration delivery and telemetry collection continue. A DSS-to-PSM communication outage delays delivery to that DSS and causes it to buffer telemetry locally. Failure of two PSM nodes removes quorum; PSM prevents new logins and configuration changes to avoid split brain, while DSSs buffer telemetry subject to local storage capacity.

Community Discussion

No comments yet. Be the first to start the discussion!

QuestionQ63

Troubleshoot

Interface 1/2/1 has an intermittent connectivity failure. You run the diag cable-diagnostic test 1/2/1 command to identify possible issues with the cable connected to the port. Match each diagnostic result to the description that helps identify the cable issue.

Drag & Drop
cable test inconclusive
no cable faults found
pair is not terminated with a link partner
short circuit with another wire pair
short circuit within the same wire pair
Explanation

Cable diagnostics report an open when a twisted pair lacks a terminating link partner, an intra-short when the two conductors of one pair are shorted, and an inter-short when conductors from different pairs are shorted. A good result indicates no cable fault; unknown means the test could not determine a conclusive result.

Community Discussion

No comments yet. Be the first to start the discussion!

That's the end of the preview

It's free

100% of the questions are free for all users.
No strings attached.

Topics covered
Plan the low-level designInstall the solutionConfigure the solutionTroubleshootCreate a monitored environmentMaintain and optimizeIntegration
Know a question that should be here? Contribute to this exam
Back home