QuestionQ30

Install and configure HPE OneView and related elements

You are creating a Logical Interconnect Group for a three-frame HPE Synergy solution that uses HPE Virtual Connect SE100Gb F32 Modules for Synergy.

In which scenario should master-module redundancy be set to highly available?

  • A When storm control or loop protection will be enabled for Virtual Connect modules
  • B When each of the frames has two Virtual Connect modules installed
  • C When each Virtual Connect module is installed in different frame
  • D When each Virtual Connect module is installed in different fabric
Explanation

High Availability redundancy requires master interconnect modules in two different Synergy frames/enclosures (on opposite sides), allowing connectivity to continue after the failure of a single interconnect or enclosure.

Learn more