HOTSPOT -
Your customer is implementing an HPE Synergy solution based on three frames.
Click each of the ports that can be used to connect satellite modules.
Your customer wants to add dedicated Fibre Channel connectivity to the HPE Synergy frame running HPE Synergy 480 Gen10 compute modules, each with one CPU socket populated. Currently they use two 12 Gb SAS switches and two HPE Virtual Connect SE 100Gb F32 Modules for HPE Synergy installed in third fabric.
What must be done to enable dedicated FC connectivity for this HPE Synergy frame?
ASAS switches must be moved to second fabric and FC modules installed in the first one.
BFor VC-FC modules, all of server facing ports must be properly licensed.
CFor Brocade switches, a logical interconnect group must be created in HPE OneView.
DA second CPU must be installed for all HPE Synergy 480 Gen10 compute nodes.
Your customer plans to deploy HPE Superdome Flex and configure two nPars, each based on two chassis.
Which components must be included in the proposal to meet the customer’s needs?
AAt least four HPE Persistent Memory DIMMs per nPar.
BOne base chassis and three expansion chassis with licenses.
CHPE Superdome Flex Grid licenses enabling connectivity between chassis.
DRack Management Controller for nPar management.
Refer to the exhibit.
Which statement about this logical interconnect group is true?
ABoth master modules are located in the same HPE Synergy frame.
BThe master modules are located in the interconnect bays 2 and 5.
CFor the given downlink speed, the maximum number of frames is reached.
DTo use interconnect bay set 3, all compute nodes must be half-height.
Question 6
Configure and quote HPE Private Cloud AI solutions using appropriate HPE tools
0
Question 7
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 8
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 9
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 10
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 11
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 12
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 13
Given a scenario, design an edge inferencing solution including selecting the correct servers, GPUs, and networking
Question 14
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 15
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 16
Configure and quote HPE Private Cloud AI solutions using appropriate HPE tools
Question 17
Configure and quote HPE Private Cloud AI solutions using appropriate HPE tools
Question 18
Configure and quote HPE Private Cloud AI solutions using appropriate HPE tools
Question 19
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 20
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 21
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 22
Configure and quote HPE Private Cloud AI solutions using appropriate HPE tools
Question 23
Describe the infrastructure components of HPE Private Cloud AI with NVIDIA
Question 24
Configure and quote HPE Private Cloud AI solutions using appropriate HPE tools
Question 25
Understand fundamental AI concepts
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ad
Want a break from the ads?
Become a Supporter and enjoy a completely ad-free experience, plus unlock Learn Mode, Exam Mode, AstroTutor AI, and more.
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Ask AstroTutor
0
Your customer plans to deploy HPE OneView for VMware vCenter Server together with HPE Storage Integration Pack for VMware vCenter. The customer wants to use them to manage HPE Synergy Gen10 compute modules, HPE ProLiant Gen10 servers and an MSA array.
Which statement about compatibility of the existing environment with the planned software components is true?
AHPE Storage Integration Pack for VMware vCenter does not support MSA arrays.
BHPE OneView for VMware vCenter Server does not support standalone HPE ProLiant servers.
CTo use the required plugins, HPE ProLiant Gen10 systems must be managed using HPE OneView.
DBoth HPE Synergy Gen10 full-height compute module plugins will require a license.
DRAG DROP -
Match each HPE Synergy logical component with the definition.
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames.
How will this change impact the customer environment?
AThe customer can add a new logical enclosure to the existing setup, because the maximum number of logical enclosures in a single management ring is not reached.
BThe customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
CThe customer has to create a new management ring for new logical enclosure, because the maximum number of frames in a single management ring is reached.
DThe customer can add a new logical enclosure to an existing setup once all required licenses are added to HPE OneView and associated with the new frames.
You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support.
Which interconnections are required to support this connection? (Choose two.)
AHPE Virtual Connect SE 100Gb F32 Module for HPE Synergy
BBrocade 16Gb Fibre Channel SAN Switch Module for HPE Synergy
CHPE Virtual Connect SE 16Gb FC Module for HPE Synergy
DHPE Virtual Connect SE 32Gb FC Module for HPE Synergy
EBrocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy
FHPE Virtual Connect SE 40Gb F8 Module for HPE Synergy
Your customer plans to add four HPE Synergy frames to an existing management ring. All installed frames are equipped with two 2-port FLM modules, while new frames will be equipped with 4-port FLM modules.
Which statement about mixing different FLM modules is true?
AExisting 2-port FLM modules must be replaced with 4-port FLM modules.
BMixing different FLM modules is allowed if all of them have the same firmware version.
CA management ring with mixed FLM modules cannot have more than 12 frames.
DA management ring can contain mixed frame link module configurations.
Your customer plans to deploy VMware ESXi 7.0 U2, and they are looking for a hardware platform that will allow them to use up to 16 CPU sockets.
Which HPE compute system meets the customer requirements?
AHPE ProLiant DL380 Gen10 Plus
BHPE ProLiant DL580 Gen10
CHPE Synergy 480 Gen10 Plus
DHPE Superdome Flex system
Which statement about the HPE D3940 storage module is true?
AUp to five modules can be installed in a single frame with Gen10 servers.
BOnly one type of drives (SATA, SAS, SSD) can be installed in each module.
CSATA drives require redundant IO adapters to be installed in this module.
DIt is configured through CLI available from HPE Synergy console.
Your customer plans to deploy VMware ESXi 7.0 U2, and they are looking for a hardware platform that will allow them to use up to 24 TB of physical memory.
Which HPE compute system meets this customer’s requirements?
AHPE ProLiant DL380 Gen10 Plus
BHPE ProLiant DL580 Gen10
CHPE Synergy 480 Gen10 Plus
DHPE Superdome Flex 280
Which statement about HPE Superdome Flex 280 is true?
AIt must be equipped with at least 768 GB of memory.
BIt supports 2 to 8 sockets in 2-socket increments.
CIt cannot be managed using HPE OneView.
DIt can support up to two nPars with an external RMC.
Your customer wants to compare HPE Superdome Flex with HPE Superdome Flex 280.
Which statement about these two systems is true?
AOnly HPE Superdome Flex 280 can support multiple nPars.
COnly HPE Superdome Flex 280 can be managed using HPE OneView.
DOnly HPE Superdome Flex supports 32 sockets and 48TB of memory.
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They plan to use Distributed Switches and DRS cluster.
You are preparing a proposal with the following components:
HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
an appropriate number of the vSphere Standard license for each compute node
one HPE D3940 Storage Modules with 40 SSDs - all required cables and options
Which statement about this proposal is true?
A2 additional HPE Synergy 480 Gen10 Plus compute modules can be added to this setup.
BvSphere Standard licenses should be replaced with Enterprise Plus licenses to enable requested features.
C20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
DOne HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50Gb/s ILM.
Your customer plans to deploy a VMware ESXi with HPE Synergy platform. They also plan a vSAN deployment leveraging HPE D3940 Storage Modules and SSD drives.
The customer requested the following components:
HPE Synergy frame with ten HPE Synergy 480 Gen10 Plus compute modules
Two HPE Virtual Connect SE 100Gb F32 Modules for Synergy
An appropriate number of vSAN Standard licenses for each compute node
One HPE D3940 Storage Module with 40 SSDs – All required cables and options
Which statement about this request is true?
AvSphere licenses should be added, as vSAN licenses do not replace vSphere licenses.
BvSphere Standard licenses should be replaced with Enterprise Plus licenses to enable vSAN.
C20 SSD drives should be removed from this setup, as D3940 supports only 20 SSD or SAS drives.
DOne HPE Virtual Connect SE 100Gb F32 Module for Synergy should be replaced with 50Gb/s ILM.
Your customer has an HPE Synergy platform deployed and managed using HPE OneView. The customer also has HPE Superdome Flex with RMC deployed. They plan to deploy a second nPar and HPE Superdome Flex 280. They play to manage new components using HPE OneView.
What must be done to achieve this goal?
AThe customer must use iLO5 to add HPE Superdome Flex systems to HPE OneView.
BThe customer should deploy an HPE OneView appliance for HPE Superdome Flex management.
CThe customer must add a second Rack Management Controller for HPE Superdome Flex 280.
DThe customer has to add HPE Superdome Flex to the HPE OneView used to manage HPE Synergy.
A logical interconnect group can span on multiple HPE Synergy frames for which interconnect type?
AHPE Synergy 12 Gb SAS Connection Module
BBrocade 32GB Fibre Channel Switch Module for HPE Synergy
CHPE Virtual Connect SE 100Gb F32 Module for Synergy
DHPE Virtual Connect SE 23 Gb FC Module for Synergy
Your customer has the following HPE Synergy setup:
3 HPE Synergy 12000 Frames
4 HPE Virtual Connect SE 100 Gb F32 Modules
2 HPE Synergy 50 Gb Interconnect Link Modules
36 HPE Synergy 480 Gen10 Plus compute modules
2 HPE Composer 2 modules
Which statement about this setup is true?
ATo manage all frames, the customer must buy two additional HPE Composer 2 modules
BThe customer must buy 36 HPE OneView Advanced licenses to manage compute modules.
CThe customer can add one D3940 Storage Module to each of the frames.
DTo use all compute nodes, the customer must create at least two logical enclosures.
Your customer has the following HPE Synergy setup:
Three frames fully populated with HPE Synergy 480 Gen10 Plus modules and 25Gb/s downlink speed formulating a single logical enclosure
Two HPE Virtual Connect SE 100Gb F32 Module for Synergy
Four HPE Synergy 50Gb Interconnect Link Module
Six HPE Synergy Virtual Connect SE 32Gb FC Modules
The customer needs to add a frame.
Which statement about the expansion of this setup is true?
AThe additional frame must have HPE Virtual Connect FC modules installed.
BThe customer has to create a new logical enclosure for the additional frame.
CThe customer can grow the existing logical enclosure up to 5 frames.
DThe additional frame cannot have 12Gb SAS connection modules installed.
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXi system.
What is required from the VMware side to enable LAG?
AVirtual Distributed Switch.
BLoad-balancing cluster.
CvSphere Standard license.
DDedicated VMkernel port.
Refer to the exhibit.
Which statement about this logical interconnect group is true?
AAn additional license is required to change the enclosure count.
BInterconnect modules are installed in interconnect bays 1 and 4.
CFor an uplink set, ports from different modules can be selected.
DBoth modules are located in different frames to redundancy.
What is a limitation when creating a server profile?
ABIOS settings can be changed only when UEFI optimized is selected as boot mode.
BIt is not possible to create shared volumes on demand through a server profile.
CiLO management is limited to the integration with Active Directory or LDAP.
DAdministrator cannot define more than 8 connections within a server profile.
What is a restriction of using a RoCE network?
AIt is by default configured as an untagged network and cannot be a part of a network set.
BIt is not supported with HPE Virtual Connect SE 40 Gb F8 Module for HPE Synergy.
CIt does not support smart link and private network features.
DIt does not support Private VLAN and Multicast VLAN.