QuestionQ4

Identify and Resolve LTM Device Issues

An LTM device is running BIG-IP v10.2.0 software. The LTM Specialist must upgrade the LTM device to BIG-IP v11.2.0 HF1. The LTM Specialist begins the upgrade by selecting the uploaded Hotfix and installing it to an unused volume. After 10 minutes, the LTM Specialist checks the upgrade status and sees that the process is stalled at 0%.

What should the LTM Specialist verify?

  • A the selected volume has sufficient space available
  • B the base software version exists on the LTM device
  • C the LTM device has been restarted into maintenance mode
  • D the LTM device has an available Internet connection via the management interface
Explanation

A BIG-IP hotfix can be applied only after its associated base software image is installed. BIG-IP v11.2.0 must therefore exist on the target volume before BIG-IP v11.2.0 HF1 can be installed.