QuestionQ74Verified/NetworkCopy linkReport a problemAsk AstroTutorSave question Refer to the exhibit. Interface fc1/5 is offline. What action should be taken to troubleshoot this problem?AActivate the correct zoneset for VSAN 100.BUpdate the FLOGI database to contain the FLOGI entries for interface fc1/5 in VSAN 100.CUpdate the FCNs database to contain names for VSAN 100.DConfigure the upstream ports and the server ports to be in VSAN 100.Show AnswerAnswerExplanationAn NPV server interface reports an unavailable upstream port when its upstream NP ports and downstream server F ports are not in the same VSAN. Both sets of ports must be configured in VSAN 100 so the NPV device has an available upstream path.Learn moreCisco Nexus 6000 Troubleshooting Guide — NPV upstream port not availableShow comments0Show commentsCommunity DiscussionNo comments yet. Be the first to start the discussion!