QuestionQ101

VerifiedStorage Network

Question Image

Refer to the exhibit. An engineer deploys a Cisco MDS 9000 Series Switch in a SAN. N9K-1 does not learn the target WWNs, and interface fc1/4 does not operate. The engineer collected the following information about the environment:

  • MDS-A is configured as an NPV switch.
  • The storage array WWNs are in the FLOGI database of MDS-A.
  • Interfaces fc1/3 on MDS-A and fc1/4 on N9K-1 are enabled.

Which set of actions resolves the issue?

Explanation

An NPV switch uses an NP port for its uplink to the core switch, while the corresponding core-switch interface must operate as an F port. Configuring MDS-A fc1/3 as an NP port and N9K-1 fc1/4 as an F port establishes the NPV-to-NPIV link, allowing the proxied FLOGI/FDISC registrations and target WWNs to be learned.