QuestionQ22

VerifiedTroubleshoot Business Continuity & Disaster Recovery (BCDR) Failures

An administrator observes that VM replication from ClusterA to ClusterB consistently fails at the same point in the replication job.

The administrator notes the following observations:

  • The Prism dashboard shows the replication job failing during snapshot creation.
  • ClusterB storage pool and container usage is under 80%, well below capacity.
  • Network latency/pings between ClusterA and ClusterB average 3 ms, with occasional spikes to 25 ms.
  • VM event logs show frequent I/O timeout errors during the replication window.
  • Both clusters are running compatible AOS versions.

What is the most likely cause of the replication failures?

Explanation

The failure occurs consistently during snapshot replication, with I/O timeout errors in the VM logs and latency spikes from 3 ms to 25 ms, which points to unstable network conditions between the clusters interrupting the data transfer. Storage on ClusterB is under 80%, so capacity is not the cause (B). Blocked replication ports would cause every attempt to fail immediately and constantly, not intermittent timeouts while latency is mostly fine (C). Nothing in the observations indicates overlapping schedules (A).