QuestionQ8

VerifiedSAN troubleshooting

Click the Exhibit button.

Question Image

You are configuring a new NetApp ONTAP cluster and connecting its nodes to Cisco MDS SAN switches. You connect one node to switch port fc1/11 and run the commands shown in the exhibit. The SAN LIFs are enabled but not operationally online, and no SAN hosts can access their LUNs on the ONTAP cluster.

In this scenario, which configuration causes this problem?

Explanation

ONTAP FC SAN LIFs rely on N_Port ID Virtualization (NPIV) to log in to the Fibre Channel fabric with their individual virtual WWPNs over a physical FC port. NPIV must therefore be enabled on the Cisco MDS switch; without it, the SAN LIFs cannot establish their required fabric logins and remain operationally down, leaving host LUN paths inaccessible.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!