QuestionQ54

VerifiedSAN troubleshooting

Click the Exhibit button.

Question Image

After completing failover testing on a newly deployed MetroCluster configuration, several aggregates are still in a degraded state.

With reference to the exhibit, which statement is true?

Explanation

A powered-off disk shelf makes the drives on its affected plex appear failed. The aggregate can remain online through its surviving mirror plex, but its RAID status becomes mirror degraded and the failed plex is offline. NetApp’s MetroCluster testing documentation identifies this same combination of aggregate and plex states as the expected result after powering off a shelf.

Learn more

Community Discussion

No comments yet. Be the first to start the discussion!