You are configuring FC ports on front-end SAN switches for a 4-node MetroCluster configuration spanning two data centers. You must ensure that each data center serves FC LUNs when an FC port in one data center goes offline.

In this scenario, which front-end switch setting must be changed to prevent overlap when a new port comes online?

Explanation

MetroCluster uses the same WWPNs on both sides of the front-end FC fabric. If the replacement FC port logs in before the prior port is removed from the name server, duplicate-WWPN rejection can deny the new login. Changing the duplicate-WWPN rejection behavior allows the new port to take precedence and prevents port overlap.