QuestionQ1

VerifiedSAN implementation and administration

A customer has a 4-node cluster made up of a FAS8020 system and an AFF A220 system, running iSCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so the customer adds a new AFF A400 system to migrate workloads from the FAS8020 system. The customer needs to migrate data from the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.

In this scenario, which NetApp command would accomplish this task?

Explanation

volume rehost transfers a volume from a source SVM to a destination SVM. It supports SAN volumes serving mapped LUNs, including the required unmapping or optional automatic remapping of LUNs for iSCSI access. By contrast, volume move relocates a volume between aggregates only within the same SVM.

Learn more

Community Discussion