Storage Maintenance and Troubleshooting

An enterprise has deployed Huawei hybrid flash storage to host service data. To ensure data reliability, the HyperClone feature is enabled for service LUNs on the storage system. During a routine system inspection, an engineer identifies an alarm for a disconnected clone pair. After logging in to the system CLI and running the show clone secondary_lun clone_id=? command, the engineer sees that the Running Status value of a secondary LUN is Interrupted.

Which of the following is not a possible cause of this fault?

Explanation

An Interrupted HyperClone secondary LUN can be caused by abnormal system I/O processing, inadequate storage-pool capacity for clone processing, or a fault affecting the secondary LUN. System quota availability does not govern the HyperClone pair’s running status and is therefore not a cause of this interruption.