QuestionQ15

VerifiedWLAN basics

When deploying a WLAN that uses the WAC + Fit AP architecture on a customer’s production network, you discover that APs cannot come online.

Which of the following could be causes?

Choose four
Explanation

A Fit AP must obtain an IP address, have network reachability to the WAC, learn a configured CAPWAP source address or interface on the WAC, and operate in Fit mode to establish a CAPWAP tunnel and join the WAC. DHCP failures, unavailable connectivity, a missing CAPWAP source configuration, and Fat-mode AP operation can each prevent the AP from coming online.

Learn more

Community Discussion