QuestionQ17

Manage Customer Intent Documentation (CID) process to ensure the installation of the solution achieves the customer requirements

You are preparing a proposal for HPE ProLiant servers to serve as vSAN nodes in a new ESA cluster.

What is one item of information required to determine the nodes’ drive-capacity requirements?

  • A The RAID modes supported by the nodes’ storage controllers
  • B The nodes’ iSCSI capabilities
  • C The number of node failures to tolerate
  • D The desired ratio of cache versus capacity drives
Explanation

The number of node failures to tolerate determines the vSAN storage policy’s resilience overhead, such as the required replicas or erasure-coding layout. That overhead changes the raw capacity needed in each node to provide the intended usable storage capacity. Configure a Storage Policy — Azure VMware Solution

Learn more