QuestionQ31

VerifiedTroubleshooting and Administration

Refer to the exhibit displaying a Download Import Report.

Question Image

Why does firewall policy ID 1 fail to import?

Explanation

The address object REMOTE_SUBNET already exists in the ADOM database with an any interface association, while its FortiGate definition is associated with port6. That conflicting interface binding prevents the address object from being imported, so the dependent firewall policy ID 1 also fails to import. FortiManager identifies conflicts between imported objects and existing ADOM objects during import.

Learn more

Community Discussion