QuestionQ39

VerifiedPost-Deployment

An implementation engineer is attempting to generate a support bundle for a physical Dell PowerProtect Data Domain appliance that has a DIMM failure. The iDRAC session logs out every 20 seconds, so the engineer cannot finish downloading the Technical Support Report (TSR) from the iDRAC.

What two steps are part of an alternate recommended process to capture a hardware report?

Choose two
Explanation

When the iDRAC web interface is too unstable to complete a TSR download (for example due to a hardware fault like a failed DIMM), Dell's recommended alternate method is to reboot the server into the Lifecycle Controller (accessed via F10 during POST), which operates independently of the iDRAC GUI session and its timeout issues. From within Lifecycle Controller, the hardware/support logs can be exported directly to a USB flash drive connected to the system, allowing the hardware report to be captured without relying on a persistent iDRAC network session. Rebooting into BIOS setup or changing the iDRAC IP address does not provide any mechanism for collecting or exporting hardware logs.

Community Discussion