Network

An engineer needs to configure a Cisco UCS blade system managed by Cisco UCS Manager. All four connected interfaces between the blade system and the fabric interconnects must be utilized. In addition, connectivity must withstand any link failure between the I/O module and the fabric interconnects. Which action meets these requirements?

  • A Configure chassis/FEX discovery policy action to four links.
  • B Configure port aggregation with LACP policy set to default.
  • C Configure Link Group Preference to Port Channel.
  • D Configure Firmware Auto Sync Server policy to Auto Acknowledge.
Explanation

Configuring Link Group Preference as Port Channel causes Cisco UCS Manager to place all links from the I/O module to the fabric interconnect into a fabric port channel. The member links are thereby used as an aggregated, redundant connection, allowing connectivity to remain available if an individual member link fails.