QuestionQ284

Network

Question Image

Refer to the exhibit. A network engineer needs to configure ports E1/31-32 on Cisco fabric interconnects A and B so they forward only VLAN 200 storage-server traffic.

Ports E1/31-32 are not reserved for any other traffic. Which port type must be configured to achieve this goal?

  • A FCoE storage
  • B uplink
  • C unified uplink
  • D FCoE uplink
Explanation

An FCoE uplink is the fabric-interconnect Ethernet interface type used to connect to an upstream FCoE-capable switch and carry Fibre Channel traffic only. Mapping the storage VSAN to FCoE VLAN 200 confines these links to that storage traffic. A unified uplink carries both Ethernet and Fibre Channel traffic, and an Ethernet uplink is not dedicated to FCoE.