Which two API calls trigger a device-configuration sync in Cisco DNA Center?

Choose two
Explanation

Cisco DNA Center triggers device configuration synchronization through the PUT operation on /dna/intent/api/v1/network-device, which synchronizes the supplied device input, and through PUT /dna/intent/api/v1/network-device/sync, the Sync Devices operation. The latter operation is documented as synchronizing devices and supports the optional forceSync parameter.